Call 08048964312 91% Response Rate

Send Email

Series Reactors

Design of Optimal Reactive Power Compensation Scheme

With reactive power compensation scheme Power factor is improved and Harmonics are suppressed leading to less electricity bill with convincing payback period. Providing short time current for 2 seconds that is 16.66 times the rate current, the HT Reactors are made available to the clients in a variety of kinds such as dry type and oil natural cooled. The assortment of rectors is extensively used in diverse applications such as neutral end of capacitors, line end, harmonic suppression and in rush current restraining and fortuned applications.

ERDA Certified.

Technical Specification:

System Voltage

3.3KV to 33KV AC, 50Hz/60Hz (Other voltage ratings on request)

Rated KVAR

50KVAr to 10MVAr

Detuning Factor

0.2% to 14%

Type

Copper or Aluminum

Linearity

more than 200%

Available in Single Tap/ Multi Tap configuration

Features

  • Efficient Power Generation
  • Efficient Hydrogen Production
  • Optimum performance
  • Better functionality

Application

  • Fortuned application also
  • Line End / Neutral end of capacitors
  • For harmonic suppression and inrush current limiting

LT Series Reactor

LT Series Reactor
  • LT Series Reactor
  • LT Series Reactor
  • LT Series Reactor
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
PhaseThree Phase
Reactor TypeIron Core Reactors
MaterialAluminum
Voltage415V
Rated KVAR6.25- 400KVAR
Applicable standardsIEC 60076-6
Detuning Factor7% & 14%
Linearity200%
The 400 KVAR LT Series Reactor is an inductive device used in low voltage power systems to provide reactive power compensation, and help improve power factor while also mitigating harmonic distortion.
Yes! I am InterestedRequest A Callback

HV Series Reactor

HV Series Reactor
  • HV Series Reactor
  • HV Series Reactor
  • HV Series Reactor
  • HV Series Reactor
  • HV Series Reactor
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Reactor TypeDry Type Reactors
MaterialAluminium/Copper
Usage/ApplicationTransmission & Distribution Networks
PowerElectrical
Frequency50Hz
PhaseSingle Phase / Three Phase
Rated KVAR50KVAR-10MVAR
LinearityMore than 200%
detuning factor0.2% to 14%
ConfigurationSingle Tap or Multi Tap
Type Of CoreAir/Iron Core
Applicable StandardsIS 5553 and IEC 60076-6
Voltage3.3-33KV
Country of OriginMade in India

MV & HV Series reactor for inrush current limiting & Harmonic Mitigation. Providing short time current for 2 seconds that is 16.66 times the rate current, the HT Reactors are made available to the clients in a variety of kinds such as dry type and oil natural cooled. 

Yes! I am InterestedRequest A Callback

LV Series Reactor

LV Series Reactor
  • LV Series Reactor
  • LV Series Reactor
  • LV Series Reactor
  • LV Series Reactor
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Reactor TypeIron Core Reactors
MaterialAluminium
BrandCLARIANT
TypeLow Voltage
Frequency50Hz
PowerElectric
Phase3
Rating6.25-400KVAR
ConfigurationSingle Tap/ Multi Tap
Voltage400-1000V AC
Detuning Factor0.2% to 14%
Country of OriginMade in India
A Detuned Filter LV Series Reactor for Inrush Current Limiting and Harmonic Mitigation is a key component in power quality systems, particularly used in low-voltage (LT) electrical networks.
Yes! I am InterestedRequest A Callback

EXPLORE MORE CATEGORIES

© Clariant Power System Limited. All Rights Reserved (Terms of Use)Developed and managed by IndiaMART InterMESH Ltd.